The BATM Alarm is programmed remotely using SMS messages.

Tip

You must program the Alarm before deploying it.

Table of Contents:

Table of Contents
maxLevel3
minLevel2

Alarm Name

The Alarm Name is used as an identifier which is sent with every outgoing SMS message to you.

name

Syntax:

Code Block
name BT123456

Specifies a unique identifier for the Alarm.

Maximum 20 characters.

We recommend that you use the serial number of the BATM in which the Alarm will be deployed.

  • The BATM s/n is located on the external manufacturing sticker, or on the Administration screen of your BATM.

The Alarm will confirm via SMS reply:

  • "Name of BATM ALARM was successfully updated to: BT123456"


Alert Recipients

The Alarm will send notifications to listed (and approved) recipients.

  • Recipients receive notifications when an alarm has been triggered.

  • Recipients have permission to arm & disarm.

Note:

  • We recommend limiting your Alert Recipients to a minimum.

  • Each outgoing SMS takes about 5-10 sec depending on signal strength, GSM network traffic, etc.

  • The alarm cannot receive AND send SMS messages simultaneously.

  • While sending an SMS it is not possible to receive an SMS until all outgoing alerts are completed, so incoming SMS commands will be delayed.

  • If there aren’t many alerts to send, the alarm will respond more quickly.

add

Syntax:

Code Block
add +420123456789

Adds Alert Recipient(s).

Separate numbers with spaces.

Maximum 10 entries (total).

Parameter notes:

  • Separate multiple numbers with spaces.

  • Do not exceed 160 characters per message (SMS limit).

  • Every telephone number MUST include the “+” and country code and can be up to 20 digits long.

  • Store up to 10 telephone numbers (total).

The Alarm will confirm via SMS reply:

  • "Add command successful: Read numbers: X  Added numbers: Y Numbers already in memory: Z"

  • X = quantity of #'s read from received SMS,

  • Y = quantity of #'s written into memory, and

  • Z = quantity of #'s already in memory.

Alert Recipients will receive a notification from the alarm after being successfully “added”.

Warning

Any attempt to save more than 10 telephone numbers (aggregate),

  • will receive this reply: "Sorry, internal memory is full. "


remove

Syntax:

Code Block
remove +420123456789

Removes Alert Recipient(s).

Separate numbers with spaces.

Parameter notes:

  • Separate multiple numbers with spaces.

  • Do not exceed 160 characters per message (SMS limit).

  • Every telephone number MUST include the “+” and country code and can be up to 20 digits long.

  • Store up to 10 telephone numbers (total).

The Alarm will confirm via SMS reply:

  • "Remove command successful: Read numbers: X  Removed numbers: Y Numbers not in memory: Z"

  • X = quantity of #'s read from received SMS,

  • Y = quantity of #'s deleted from memory, and

  • Z = quantity of #'s that weren’t located.

Every removed telephone number is sent an SMS text:

  • "This number will be removed from BATM ALARM " ( + the Alarm Name )

Filter by label (Content by label)
showLabelsfalse
max5
spacescom.atlassian.confluence.content.render.xhtml.model.resource.identifiers.SpaceResourceIdentifier@10d56
showSpacefalse
sortmodified
typepage
reversetrue
labelsalarm kb-how-to-article
cqllabel in ( "kb-how-to-article" , "alarm" ) and type = "page" and space = "ESD"
Page Properties
hiddentrue

Related issues